Silo overfill protection is continuous 3D-LiDAR fill-level capture with a configurable low / high / critical threshold cascade. ATEX-ready hardware, interlocked PLC stop logic via OPC UA — built for plant-safety and compliance teams. Delivered by OWL EYE®.
Silo-Überfüllsicherung ist kontinuierliche 3D-LiDAR-Füllstand-Erfassung mit konfigurierbarer Niedrig- / Hoch- / Kritisch-Kaskade. ATEX-taugliche Hardware, verriegelte SPS-Stop-Logik über OPC UA — gebaut für Anlagensicherheit und Compliance. Geliefert von OWL EYE®.
Silo overfill protection is continuous 3D-LiDAR fill-level capture with a configurable low / high / critical threshold cascade. ATEX-ready hardware, interlocked PLC stop logic via OPC UA — built for plant-safety and compliance teams. Delivered by OWL EYE®.
Silo overfill protection is a safety function, not a convenience. A blocked vent, a delayed alarm or a stuck mechanical paddle can lead to dust release, pressurised dome failure, downstream damage to filters, screws and discharge cones — and, in combustible bulk, to a deflagration scenario the operator never wanted to be in.Silo-Überfüllsicherung ist eine Sicherheitsfunktion, kein Komfort-Feature. Ein verstopftes Belüftungsventil, ein verzögerter Alarm oder ein klemmendes mechanisches Paddel können zu Staubaustritt, Dachversagen, Folgeschäden an Filtern, Schnecken und Auslauftrichtern führen — und bei brennbarem Schüttgut zu einem Verpuffungsszenario, in dem der Betreiber nie sein wollte.Silo overfill protection is a safety function, not a convenience. A blocked vent, a delayed alarm or a stuck mechanical paddle can lead to dust release, pressurised dome failure, downstream damage to filters, screws and discharge cones — and, in combustible bulk, to a deflagration scenario the operator never wanted to be in.
OWL EYE® overfill protection replaces the single-point switch with a continuous LiDAR fill-level signal. The sensor sees the entire surface from above, so threshold logic acts on real remaining volume — not on whether one paddle moved. ATEX-ready housings, hermetic optical windows and a self-test heartbeat to the PLC turn overfill prevention into a verifiable safety chain.Die OWL EYE® Überfüllsicherung ersetzt den Einzelpunkt-Schalter durch ein kontinuierliches LiDAR-Füllstandssignal. Der Sensor erfasst die gesamte Oberfläche von oben — die Schwellwert-Logik arbeitet auf realem Restvolumen, nicht auf der Frage, ob ein Paddel gerade ausgelenkt ist. ATEX-taugliche Gehäuse, hermetisch dichtes Sichtfenster und ein Selbsttest-Heartbeat zur SPS machen aus der Überfüllsicherung eine prüfbare Sicherheitskette.OWL EYE® overfill protection replaces the single-point switch with a continuous LiDAR fill-level signal. The sensor sees the entire surface from above, so threshold logic acts on real remaining volume — not on whether one paddle moved. ATEX-ready housings, hermetic optical windows and a self-test heartbeat to the PLC turn overfill prevention into a verifiable safety chain.
Built as a layered safeguard alongside the wider OWL EYE® BUNKERS & FEEDERS platform — same sensor, same dashboard, audit-ready alarm log.Aufgebaut als zusätzliche Schutzebene neben der OWL EYE® BUNKER & FEEDER-Plattform — gleicher Sensor, gleiches Dashboard, revisionssicheres Alarmprotokoll.Built as a layered safeguard alongside the wider OWL EYE® BUNKERS & FEEDERS platform — same sensor, same dashboard, audit-ready alarm log.
Overfill-protection threshold pipelines in production at K+S receiving silos and Nordzucker beet feeders. Schwellwert-Überfüllsicherung im Produktiv-Betrieb bei K+S-Annahmesilos und Nordzucker-Rüben-Aufgaben. Overfill-protection threshold pipelines in production at K+S receiving silos and Nordzucker beet feeders.
A 3D-LiDAR sensor mounted above the silo scans the surface continuously. Remaining volume is computed every second; configurable low / high / critical thresholds trigger graded responses — from operator notice to hard PLC interlock. Ein 3D-LiDAR-Sensor über dem Silo erfasst die Oberfläche kontinuierlich. Das Restvolumen wird im Sekundentakt berechnet; konfigurierbare Niedrig- / Hoch- / Kritisch-Schwellwerte lösen abgestufte Reaktionen aus — vom Bediener-Hinweis bis zur harten SPS-Verriegelung. A 3D-LiDAR sensor mounted above the silo scans the surface continuously. Remaining volume is computed every second; configurable low / high / critical thresholds trigger graded responses — from operator notice to hard PLC interlock.
Hermetic optical window, intrinsically safe wiring options and enclosure variants for Zone 22 dust atmospheres — suited for grain, sugar, charcoal, wood-pellet and chemical silos. Hermetisch dichtes Sichtfenster, eigensichere Verdrahtungs-Optionen und Gehäusevarianten für Zone-22-Staubatmosphäre — geeignet für Getreide-, Zucker-, Holzkohle-, Pellet- und Chemie-Silos. Hermetic optical window, intrinsically safe wiring options and enclosure variants for Zone 22 dust atmospheres — suited for grain, sugar, charcoal, wood-pellet and chemical silos.
Per-silo, per-material low / high / critical limits with hysteresis and time filtering. No alarm flooding during normal fill cycles, no missed event on a slow creep into the dome. Pro Silo, pro Material — Niedrig- / Hoch- / Kritisch-Grenzwerte mit Hysterese und Zeitfilter. Keine Alarmflut bei normalen Füllzyklen, kein verpasstes Ereignis bei langsamer Annäherung an die Dachkuppel. Per-silo, per-material low / high / critical limits with hysteresis and time filtering. No alarm flooding during normal fill cycles, no missed event on a slow creep into the dome.
Hard-wired interlock contacts plus OPC UA into your DCS or SCADA. Heartbeat self-test confirms the sensor is alive — every cycle, to the PLC, into the alarm log. Potentialfreie Verriegelungs-Kontakte plus OPC UA in PLS oder SCADA. Selbsttest-Heartbeat bestätigt jeden Zyklus, dass der Sensor aktiv ist — zur SPS, ins Alarmprotokoll. Hard-wired interlock contacts plus OPC UA into your DCS or SCADA. Heartbeat self-test confirms the sensor is alive — every cycle, to the PLC, into the alarm log.
Wherever an uncontrolled overfill threatens equipment, atmosphere or downstream process — an OWL EYE® overfill safeguard belongs. Wo unkontrollierte Überfüllung Anlage, Atmosphäre oder Folgeprozess gefährdet — gehört eine OWL EYE® Überfüllsicherung hin. Wherever an uncontrolled overfill threatens equipment, atmosphere or downstream process — an OWL EYE® overfill safeguard belongs.
| Dimension | Mechanical high-level switch | OWL EYE® LiDAR overfill protection |
|---|---|---|
| Signal type | single point, binary | continuous fill level + remaining volume |
| Failure detection | only at periodic manual test | heartbeat to PLC every cycle |
| Threshold levels | one fixed switch height | low / high / critical, configurable |
| Asymmetric build-up / bridging | invisible | flagged from surface scan |
| Material contact | paddle in the bulk — wears, jams | none — sensor above the surface |
| ATEX dust zones | available, but mechanically vulnerable | enclosure variants for Zone 22 |
| Audit trail | manual test logs | continuous alarm log with timestamps |
| Kriterium | Mechanischer Hochfüllschalter | OWL EYE® LiDAR-Überfüllsicherung |
|---|---|---|
| Signalart | Einzelpunkt, binär | kontinuierlicher Füllstand + Restvolumen |
| Fehlererkennung | nur bei manueller Funktionsprüfung | Heartbeat zur SPS in jedem Zyklus |
| Schwellwert-Stufen | eine feste Schaltpunkt-Höhe | Niedrig / Hoch / Kritisch, konfigurierbar |
| Asymmetrische Aufbauten / Brückenbildung | unsichtbar | aus Oberflächen-Scan erkannt |
| Materialkontakt | Paddel im Schüttgut — verschleißt, klemmt | keiner — Sensor über der Oberfläche |
| ATEX-Staubzonen | verfügbar, aber mechanisch anfällig | Gehäusevarianten für Zone 22 |
| Audit-Trail | manuelle Prüfprotokolle | kontinuierliches Alarmprotokoll mit Zeitstempel |
| Dimension | Mechanical high-level switch | OWL EYE® LiDAR overfill protection |
|---|---|---|
| Signal type | single point, binary | continuous fill level + remaining volume |
| Failure detection | only at periodic manual test | heartbeat to PLC every cycle |
| Threshold levels | one fixed switch height | low / high / critical, configurable |
| Asymmetric build-up / bridging | invisible | flagged from surface scan |
| Material contact | paddle in the bulk — wears, jams | none — sensor above the surface |
| ATEX dust zones | available, but mechanically vulnerable | enclosure variants for Zone 22 |
| Audit trail | manual test logs | continuous alarm log with timestamps |
Compliance, ATEX and integration questions safety engineers ask before specifying LiDAR-based silo overfill protection. Compliance-, ATEX- und Integrations-Fragen, die Sicherheitsingenieure stellen, bevor sie eine LiDAR-basierte Silo-Überfüllsicherung spezifizieren. Compliance, ATEX and integration questions safety engineers ask before specifying LiDAR-based silo overfill protection.